1. Equipment Overview
The building engineering one-card system tr*ning platform is based on the development trend and characteristics of the intelligent building industry, combined with the functions and applications of building intelligent technology, and guided by the work tasks of the building 5A subsystem. It is based on the comprehensive application and expansion of various technologies such as building intelligence, industrial automation, computer network communication, integrated wiring and system integration. It meets the system and principle demonstration, skill display, work task design and planning, tr*ning, process and result evaluation, assessment, appr*sal, competition, engineering project design and graduation design of technicians and vocational colleges in building intelligent equipment installation and operation, building equipment installation, automation control, computer network and communication system engineering and other related majors; it systematically tr*ns students' professional skills, practical hands-on skills (installation, wiring, wiring, programming, debugging, operation, m*ntenance and rep*r, etc.), design planning, communication, teamwork, efficiency awareness and innovative thinking, and at the same time cultivates their rigorous work style and good professionalism.
2. Technical indicators
(1) Power input: single-phase three-wire (third-party grounding), AC220V±10%, 50/60Hz;
(2) Safety protection: grounding, leakage (operating current ≤30mA), overvoltage, overload, short circuit;
(3) Power consumption of the whole machine: ≤300W;
Overall dimensions (width×height×depth): 1060mm×1900mm×800mm (industrial aluminum profile bracket);
3. Tr*ning projects
1) System installation, wiring, connection, programming, debugging, operation, m*ntenance and rep*r;
2) Setting, detecting and troubleshooting of line faults;
3) Tr*ning on different types of defense zones and setting their parameters;
4) Tr*ning on different types of defense and setting their parameters;
5) Recognize and be familiar with various IC card access control system equipment, configuration and functions;
6) Connection and debugging of system equipment: forming single-door control system, double-door control system, single-door entry and exit card swiping control system, single-door and double-door combination or single-door and double-door linkage control system;
7) Software installation, card reader testing, controller address setting, etc. of IC card access control management system;
8) Run management software to modify system settings, controller settings and user settings, etc.;
9) Recognition, issuance and management of IC cards of different functional nature (user card, privilege card, management mother card);
10) Operation and operation of system management software linkage, deployment, map and query record;
11) Setting, debugging, operation and exercise of IC card access control management system;
12) Wiring, operation and management of attendance machine;
13) Wiring, operation and management of consumption machine;
14) Operation of smart card management software;
15) Operation and management of card issuance;
16) Connection, debugging and management of smart card system integration.
17) Installation and wiring of bridge and its bracket;
18) Installation of information socket and rack equipment;
19) Production and testing of crystal head and jumper;
20) Pressing and testing of RJ45 module and patch panel;
21) Connection of RJ45 jumper and link testing.
4. Virtual simulation software for electrical installation of building and intelligent building Designed based on unity3d, users can choose different sizes of interactive interface according to computer configuration, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It has the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and wrong choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: sprinkler, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pressure gauge, high-level water tank, Wia control cabinet, pressure regulating tank, flow switch, end water test device, dr*nage facilities, water pump connector, hydraulic alarm, delay, wet alarm, butterfly valve, check valve, fire pump, safety pressure regulating valve, fire water tank. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, 3D model is semi-transparent, and the internal water flow can be seen. Equipped with exercise module (4 multiple-choice questions are built-in, and there are prompts for correct and wrong choices) 4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score are displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment recognition: There are optimal viewing angles, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (8 built-in multiple-choice questions, and there are prompts for correct and wrong choices), and schematic diagrams (you can enter the equipment from the schematic diagram). The equipment includes: nozzles, HFC-227 storage bottles, bottle head valves, heptafluoropropane check valves, high-pressure hoses, gas check valves, safety valves, weighing alarms, electromagnetic starters, selection valves, smoke alarms, and fire alarm controllers. 3. Principle display: Display the working principle of the gas fire extinguishing system, 3D animation demonstrations, and 3D models are semi-transparent, and the internal gas can be seen. Equipped with practice module (built-in 3 multiple-choice questions, with prompts for correct and wrong choices) 4. Design and layout: There are 6 multiple-choice questions, each with scores, and the correct answer and score will be displayed after submission . C. Escape drill: Teaching in the form of fun games, escape from the burning room within a limited time, and wrong choices will directly enter the score interface.
5. M*n configuration
欢迎咨询YLLY-YK Building Engineering Card System Experimental Platform相关问题,我们是源头工厂,有标准工业厂房生产基地,欢迎前来考察,如有YLLY-YK Building Engineering Card System Experimental Platform其他问题,可联系19957812178
The building engineering one-card system tr*ning platform is based on the development trend and characteristics of the intelligent building industry, combined with the functions and applications of building intelligent technology, and guided by the work tasks of the building 5A subsystem. It is based on the comprehensive application and expansion of various technologies such as building intelligence, industrial automation, computer network communication, integrated wiring and system integration. It meets the system and principle demonstration, skill display, work task design and planning, tr*ning, process and result evaluation, assessment, appr*sal, competition, engineering project design and graduation design of technicians and vocational colleges in building intelligent equipment installation and operation, building equipment installation, automation control, computer network and communication system engineering and other related majors; it systematically tr*ns students' professional skills, practical hands-on skills (installation, wiring, wiring, programming, debugging, operation, m*ntenance and rep*r, etc.), design planning, communication, teamwork, efficiency awareness and innovative thinking, and at the same time cultivates their rigorous work style and good professionalism.
2. Technical indicators
(1) Power input: single-phase three-wire (third-party grounding), AC220V±10%, 50/60Hz;
(2) Safety protection: grounding, leakage (operating current ≤30mA), overvoltage, overload, short circuit;
(3) Power consumption of the whole machine: ≤300W;
Overall dimensions (width×height×depth): 1060mm×1900mm×800mm (industrial aluminum profile bracket);
3. Tr*ning projects
1) System installation, wiring, connection, programming, debugging, operation, m*ntenance and rep*r;
2) Setting, detecting and troubleshooting of line faults;
3) Tr*ning on different types of defense zones and setting their parameters;
4) Tr*ning on different types of defense and setting their parameters;
5) Recognize and be familiar with various IC card access control system equipment, configuration and functions;
6) Connection and debugging of system equipment: forming single-door control system, double-door control system, single-door entry and exit card swiping control system, single-door and double-door combination or single-door and double-door linkage control system;
7) Software installation, card reader testing, controller address setting, etc. of IC card access control management system;
8) Run management software to modify system settings, controller settings and user settings, etc.;
9) Recognition, issuance and management of IC cards of different functional nature (user card, privilege card, management mother card);
10) Operation and operation of system management software linkage, deployment, map and query record;
11) Setting, debugging, operation and exercise of IC card access control management system;
12) Wiring, operation and management of attendance machine;
13) Wiring, operation and management of consumption machine;
14) Operation of smart card management software;
15) Operation and management of card issuance;
16) Connection, debugging and management of smart card system integration.
17) Installation and wiring of bridge and its bracket;
18) Installation of information socket and rack equipment;
19) Production and testing of crystal head and jumper;
20) Pressing and testing of RJ45 module and patch panel;
21) Connection of RJ45 jumper and link testing.
4. Virtual simulation software for electrical installation of building and intelligent building Designed based on unity3d, users can choose different sizes of interactive interface according to computer configuration, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It has the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and wrong choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: sprinkler, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pressure gauge, high-level water tank, Wia control cabinet, pressure regulating tank, flow switch, end water test device, dr*nage facilities, water pump connector, hydraulic alarm, delay, wet alarm, butterfly valve, check valve, fire pump, safety pressure regulating valve, fire water tank. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, 3D model is semi-transparent, and the internal water flow can be seen. Equipped with exercise module (4 multiple-choice questions are built-in, and there are prompts for correct and wrong choices) 4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score are displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment recognition: There are optimal viewing angles, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (8 built-in multiple-choice questions, and there are prompts for correct and wrong choices), and schematic diagrams (you can enter the equipment from the schematic diagram). The equipment includes: nozzles, HFC-227 storage bottles, bottle head valves, heptafluoropropane check valves, high-pressure hoses, gas check valves, safety valves, weighing alarms, electromagnetic starters, selection valves, smoke alarms, and fire alarm controllers. 3. Principle display: Display the working principle of the gas fire extinguishing system, 3D animation demonstrations, and 3D models are semi-transparent, and the internal gas can be seen. Equipped with practice module (built-in 3 multiple-choice questions, with prompts for correct and wrong choices) 4. Design and layout: There are 6 multiple-choice questions, each with scores, and the correct answer and score will be displayed after submission . C. Escape drill: Teaching in the form of fun games, escape from the burning room within a limited time, and wrong choices will directly enter the score interface.
5. M*n configuration
Serial number | Equipment Name | quantity | unit | Remark |
1 | Vertical tr*ning platform | 1 | tower | |
2 | Mesh plate installation module | 8 | piece | |
3 | Expansion fixings for mesh panels | 100 | indivual | |
4 | Cable Management | 12 | indivual | |
5 | Power Management Module | 1 | tower | |
6 | Embedded programming host and display module | 1 | set | |
7 | Single door network access controller | 1 | tower | |
8 | Double door network access controller | 1 | tower | |
9 | Communication converter | 1 | indivual | |
10 | Card issuer | 1 | indivual | |
11 | Card reader | 1 | indivual | |
12 | Card reader with keyboard and LCD display | 1 | indivual | |
13 | Attendance Machine | 1 | tower | |
14 | Consumer Machine | 1 | tower | |
15 | Patrol stick | 1 | tower | |
16 | Patrol Point | 2 | indivual | |
17 | Inductive IC card | 4 | open | |
18 | Electric Bolt Lock | 1 | Bundle | |
19 | Electromagnetic lock | 1 | Bundle | |
20 | Electromagnetic lock controller | 1 | indivual | |
twenty one | Door opening button | 1 | indivual | |
twenty two | Card management system software | 1 | set | |
twenty three | 6-bit PD power supply | 1 | indivual | |
twenty four | 24-position Category 5e non-shielded socket patch panel | 1 | indivual | |
25 | 8P8C Category 5e non-shielded crystal head | 20 | indivual | |
26 | Category 5e non-shielded information socket module | 4 | indivual | |
27 | Single port 86 type information panel | 4 | indivual | |
28 | 86 type bottom box | 4 | indivual | |
29 | TP Category 5e 4 p*rs of unshielded patch cord | 4 | strip | |
30 | TP Category 5e 4-p*r unshielded cable | 100 | rice | |
31 | Special bridge | 1 | set | |
32 | Consumables and tools | 1 | set | Wires of various specifications, common electrical tools and cable testers, etc. |