Product


1. Overview
The inductive IC card parking system adopts inductive IC card reading technology, integrating advanced and mature technologies such as radio frequency card technology, automatic road gate, vehicle
sensing technology, industrial control technology, etc. into the system. 2. Features
1. The system includes automatic gates, vehicle detectors, entrance control machines, exit control machines, parking management software, temporary card meter, and image system in actual projects; 2. The system charges by IC card or paper ticket.
3. Technical parameters
1. System operating voltage: single-phase three-wire 220V±5%50Hz
2. Machine capacity: <3.5kVA
2. Dimensions: about 1668mm×805mm×1484mm
4. Safety protection: with automatic leakage protection device
4. Tr*ning projects
1. Introduction to the working principle of each component of the system
2. Software operation
3. Entry control
4. Exit control
5. System scenario simulation
5. Basic configuration
1. Parking system simulation screen (iron double-layer matte dense spray structure)
(1) AC power supply Provide AC power: single-phase AC 220V50Hz (2) Simulated parking system (3) Parking management system structure diagram
2. Building tr*ning table
The tr*ning table is an iron double-layer matte dense spray structure. The desktop is a fireproof, waterproof, wear-resistant high-density board with a solid structure and a rectangular closed structure. It is beautiful and elegant; it is equipped with two large drawers and cabinet doors for placing tools, hanging accessories and materials. The desktop is used to install the power control screen and provide a spacious and comfortable work surface. The tr*ning table is also equipped with four universal wheels and four fixed adjustment mechanisms , which are easy to move and fix, and are conducive to the layout of the tr*ning room.
3. Entrance control machine
The entrance control machine is the entrance control core of the embedded intelligent control unit, providing automatic control functions, and is used in parking management systems that have both monthly card vehicles and temporary vehicles. The entrance control machine can work online or offline independently. The intelligent control unit not only has an independent control program, clock, memory and various inputs and outputs, but also has a CAN bus networking interface. When working offline independently, it can temporarily store tens of thousands of offline records and automatically upload them after networking.
4. Exit control machine
The exit control machine is the exit self-service card reading control core of the embedded intelligent control unit, providing automatic control functions, improving the efficiency of vehicle exit, and achieving unattended management of monthly card vehicles. The intelligent control unit has an independent control program, clock, memory and various inputs and outputs, and also has a CAN bus networking interface. When working offline independently, it can temporarily store tens of thousands of offline records and automatically upload them after networking.
5. Exit cash register
The POS cash register is the center of control, charging and management in the parking fee management system. The built-in intelligent control unit and storage unit provide automatic control functions as well as charging management functions, and can work independently without a computer. The POS cash register is suitable for parking management systems that combine monthly card vehicles and temporary vehicles, and is used to monitor the communication of entrance and exit equipment, charging of temporary vehicles, system data storage, and communication with computers. It can work online with a computer and can work independently without a computer. The intelligent control unit has an independent control program, clock, memory, and various input and output, and also has an advanced CAN bus networking interface. The intelligent control unit can independently store 10,000 monthly card information and tens of thousands of system event records and charging information, which can be automatically uploaded and imported into the database after being connected to the computer.
6. The gate uses a special torque motor and control circuit, which is suitable for vehicle entrances and exits in various parking management systems to limit vehicle entry and exit.
7. Virtual simulation software for electrical installation of buildings and intelligent buildings Based on unity3d design, users can choose different sizes of interactive interfaces according to computer configurations, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, the contents are as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and wrong choices), and schematic diagrams (you can enter the equipment from the schematic diagram). The equipment includes: sprinklers, water flow indicators, signal butterfly valves, exhaust valves, fire alarm controls, high-pressure gauges, high-level water tanks, Wia control cabinets, pressure-stabilizing tanks, flow switches, terminal water testing devices, dr*nage facilities, water pump connectors, hydraulic alarms, time delays, wet alarms, butterfly valves, check valves, fire pumps, safety pressure-stabilizing valves, and fire water tanks. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, and semi-transparent 3D models , so that the internal water flow can be seen. Equipped with practice module (built-in 4 multiple-choice questions, with prompts for correct and incorrect choices) 4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment recognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), practice (built-in 8 multiple-choice questions, with prompts for correct and incorrect choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane check valve, high-pressure hose, gas check valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire alarm controller.
3. Principle demonstration: Demonstrate the working principle of the gas fire extinguishing system, 3D animation demonstration, 3D model is semi-transparent, and the internal gas can be seen. Equipped with a practice module (3 built-in multiple-choice questions, with prompts for correct and incorrect choices)
4. Design layout: There are 6 multiple-choice questions, each with a score, and the correct answer and score will be displayed after submission
C. Escape drill: Use fun games to teach, escape from the burning room within a limited time, and choose the wrong answer directly to enter the score interface.
VI. Configuration list
欢迎咨询YLLY-TG Parking Lot Management System Experimental Platform相关问题,我们是源头工厂,有标准工业厂房生产基地,欢迎前来考察,如有YLLY-TG Parking Lot Management System Experimental Platform其他问题,可联系19957812178
The inductive IC card parking system adopts inductive IC card reading technology, integrating advanced and mature technologies such as radio frequency card technology, automatic road gate, vehicle
sensing technology, industrial control technology, etc. into the system. 2. Features
1. The system includes automatic gates, vehicle detectors, entrance control machines, exit control machines, parking management software, temporary card meter, and image system in actual projects; 2. The system charges by IC card or paper ticket.
3. Technical parameters
1. System operating voltage: single-phase three-wire 220V±5%50Hz
2. Machine capacity: <3.5kVA
2. Dimensions: about 1668mm×805mm×1484mm
4. Safety protection: with automatic leakage protection device
4. Tr*ning projects
1. Introduction to the working principle of each component of the system
2. Software operation
3. Entry control
4. Exit control
5. System scenario simulation
5. Basic configuration
1. Parking system simulation screen (iron double-layer matte dense spray structure)
(1) AC power supply Provide AC power: single-phase AC 220V50Hz (2) Simulated parking system (3) Parking management system structure diagram
2. Building tr*ning table
The tr*ning table is an iron double-layer matte dense spray structure. The desktop is a fireproof, waterproof, wear-resistant high-density board with a solid structure and a rectangular closed structure. It is beautiful and elegant; it is equipped with two large drawers and cabinet doors for placing tools, hanging accessories and materials. The desktop is used to install the power control screen and provide a spacious and comfortable work surface. The tr*ning table is also equipped with four universal wheels and four fixed adjustment mechanisms , which are easy to move and fix, and are conducive to the layout of the tr*ning room.
3. Entrance control machine
The entrance control machine is the entrance control core of the embedded intelligent control unit, providing automatic control functions, and is used in parking management systems that have both monthly card vehicles and temporary vehicles. The entrance control machine can work online or offline independently. The intelligent control unit not only has an independent control program, clock, memory and various inputs and outputs, but also has a CAN bus networking interface. When working offline independently, it can temporarily store tens of thousands of offline records and automatically upload them after networking.
4. Exit control machine
The exit control machine is the exit self-service card reading control core of the embedded intelligent control unit, providing automatic control functions, improving the efficiency of vehicle exit, and achieving unattended management of monthly card vehicles. The intelligent control unit has an independent control program, clock, memory and various inputs and outputs, and also has a CAN bus networking interface. When working offline independently, it can temporarily store tens of thousands of offline records and automatically upload them after networking.
5. Exit cash register
The POS cash register is the center of control, charging and management in the parking fee management system. The built-in intelligent control unit and storage unit provide automatic control functions as well as charging management functions, and can work independently without a computer. The POS cash register is suitable for parking management systems that combine monthly card vehicles and temporary vehicles, and is used to monitor the communication of entrance and exit equipment, charging of temporary vehicles, system data storage, and communication with computers. It can work online with a computer and can work independently without a computer. The intelligent control unit has an independent control program, clock, memory, and various input and output, and also has an advanced CAN bus networking interface. The intelligent control unit can independently store 10,000 monthly card information and tens of thousands of system event records and charging information, which can be automatically uploaded and imported into the database after being connected to the computer.
6. The gate uses a special torque motor and control circuit, which is suitable for vehicle entrances and exits in various parking management systems to limit vehicle entry and exit.
7. Virtual simulation software for electrical installation of buildings and intelligent buildings Based on unity3d design, users can choose different sizes of interactive interfaces according to computer configurations, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, the contents are as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and wrong choices), and schematic diagrams (you can enter the equipment from the schematic diagram). The equipment includes: sprinklers, water flow indicators, signal butterfly valves, exhaust valves, fire alarm controls, high-pressure gauges, high-level water tanks, Wia control cabinets, pressure-stabilizing tanks, flow switches, terminal water testing devices, dr*nage facilities, water pump connectors, hydraulic alarms, time delays, wet alarms, butterfly valves, check valves, fire pumps, safety pressure-stabilizing valves, and fire water tanks. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, and semi-transparent 3D models , so that the internal water flow can be seen. Equipped with practice module (built-in 4 multiple-choice questions, with prompts for correct and incorrect choices) 4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment recognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), practice (built-in 8 multiple-choice questions, with prompts for correct and incorrect choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane check valve, high-pressure hose, gas check valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire alarm controller.
3. Principle demonstration: Demonstrate the working principle of the gas fire extinguishing system, 3D animation demonstration, 3D model is semi-transparent, and the internal gas can be seen. Equipped with a practice module (3 built-in multiple-choice questions, with prompts for correct and incorrect choices)
4. Design layout: There are 6 multiple-choice questions, each with a score, and the correct answer and score will be displayed after submission
C. Escape drill: Use fun games to teach, escape from the burning room within a limited time, and choose the wrong answer directly to enter the score interface.
VI. Configuration list
Serial number | Equipment Name | Equipment specifications or models | quantity | unit | Remark |
1 | Parking system simulation screen | 1 | set | ||
2 | Tr*ning table | 1 | tower | ||
3 | Entrance ticket box system (inclusive) | 1 | set | ||
Entrance control panel | 1 | Only | |||
IC card reader module | 1 | Only | |||
Vehicle Detector | 1 | Only | |||
Ground sensor coil | 1 | set | |||
Dedicated power supply | 1 | Only | |||
Control of ballot boxes | 1 | set | |||
Automatic card dispensing machine | 1 | set | |||
Display | 1 | Only | |||
4 | Entrance automatic gate system (including below) | 1 | set | ||
Smart Gate | 1 | Only | |||
Vehicle Detector | 1 | Only | |||
Ground sensor coil | 1 | set | |||
5 | Export ticket box system (inclusive) | 1 | set | ||
Export control panel | 1 | set | |||
IC card reader module | 1 | Only | |||
Dedicated power supply | 1 | Only | |||
Control of ballot boxes | 1 | set | |||
Display | 1 | set | |||
6 | Exit gate system (including the following) | 1 | set | ||
Smart Gate | 1 | set | |||
Vehicle Detector | 1 | set | |||
Ground sensor coil | 1 | set | |||
7 | Management Center (inclusive) | 1 | set | ||
computer | 1 | set | |||
Parking management software | 1 | set | |||
8-port switch | 1 | tower | |||
IC card issuing machine | 1 | tower | |||
IC Card | 50 | open | |||
Video capture card | 1 | open | |||
Infrared integrated color camera | 2 | set | |||
Mounting brackets | 2 | set |
欢迎咨询YLLY-TG Parking Lot Management System Experimental Platform相关问题,我们是源头工厂,有标准工业厂房生产基地,欢迎前来考察,如有YLLY-TG Parking Lot Management System Experimental Platform其他问题,可联系19957812178